Bacteriological results of the IG 100 BC
Impregnated activated carbon type C 1220 IG 100 BC Bactericide!
Patented product (Patent N°INPI-06-01200)
Extraordinary findings¿
Many laboratories took an interest in our innovative product, all of them conclude in a strong bactericide power of IG100 BC on every tested bacterial strain. Last findings of ¿Groupe Santé Recherche¿ (GSR) of Toulouse (chartered clinical center of research) are eloquent.
Protocol:
Every filtering refill was inoculated with 106 cells. Filtrate has been putting back in culture and colonies¿ account done 24h after, except salmonella (14 days). Every measure has been realized three times and repetitiveness verified (two successive experiences with one interval day).
Virulent strain |
Environment
|
Time |
||||
T0 |
T1 |
T2 |
T3 |
T4 |
||
Salmonella |
Test IG100BC |
1.106 1.106 |
1.106 0 |
1.106 0 |
1.106 0 |
1.106 0 |
Virulent strain |
Environment |
Time |
||||
T0 |
T1 |
T2 |
T3 |
T4 |
||
Legionella |
Test IG100BC |
1.106 1.106 |
1.106 0 |
1.106 0 |
1.106 0 |
1.106 0 |
Virulent strain |
Environment |
Time |
||||
T0 |
T1 |
T2 |
T3 |
T4 |
||
Pseudomona |
Test IG100BC |
1.106 1.106 |
1.106 100 |
1.106 0 |
1.106 0 |
1.106 0 |
Virulent strain |
Environment |
Time |
||||
T0 |
T1 |
T2 |
T3 |
T4 |
||
Shigela |
Test IG100BC |
1.106 1.106 |
1.106 100 |
1.106 0 |
1.106 0 |
1.106 0 |
Virulent strain |
Environment |
Time |
||||
T0 |
T1 |
T2 |
T3 |
T4 |
||
E.Coli |
Test IG100BC |
1.106 1.106 |
1.106 1.105 |
1.106 1.104 |
1.106 1000 |
1.106 0 |
Virulent strain
|
Environment |
Time |
||||
T0 |
T1 |
T2 |
T3 |
T4 |
||
Staphy |
Test IG100BC |
1.106 1.106 |
1.106 1.105 |
1.106 1000 |
1.106 0 |
1.106 0 |